Sie suchten nach: Viskosimetrie-Standards

Ready-to-use viscometry standards verify that laboratory rhemoeters, viscometers, and other related measuring equipment possess a reliable calibration at all times. Using mediums with known thickness levels, accurate comparisons can be made in maintenance inspections to guarantee the apparatus performance remains consistent. Offering the highest sensitivity, oil solutions are typically designed for specific equipment designs. Popular for addressing general purpose applications, silicone fluid viscometry standards have excellent temperature stability for when levels can only be minimally controlled.

Ready-to-use viscometry standards verify that laboratory rhemoeters, viscometers, and other related measuring equipment possess a reliable calibration at all times. Using mediums with known thickness levels, accurate comparisons can be made in maintenance inspections to guarantee the apparatus performance remains consistent. Offering the highest sensitivity, oil solutions are typically designed for specific equipment designs. Popular for addressing general purpose applications, silicone fluid viscometry standards have excellent temperature stability for when levels can only be minimally controlled.


284  Ergebnisse wurden gefunden

Sort Results

Listenansicht Hybridansicht
SearchResultCount:"284"
Beschreibung: Kegel-Platte-Viskositätsstandard 20,00 °C, 21,00 °C, 22,00 °C, 23,00 °C, 24,00 °C und 25,00 °C, VWR®, Viscometry Standards, 2162/3, Viskosität bei 25 °C: 100,4 mPa·s, Testmethode: ASTM D2162 / ASTM D345, Packung: Glasflasche
Artikel-Nr: 99422.260
VE: 1 * 500 mL
Lieferant: VWR Chemicals

Beschreibung: Kegel-Platte-Viskositätsstandard 20,00 °C, 21,00 °C, 22,00 °C, 23,00 °C, 24,00 °C und 25,00 °C, VWR®, Viscometry Standards, 2162/12, Viskosität bei 25 °C: 1008 mPa·s, Testmethode: ASTM D2162 / ASTM D354, Packung: Glasflasche
Artikel-Nr: 99409.260
VE: 1 * 500 mL
Lieferant: VWR Chemicals

Beschreibung: Kegel-Platte-Viskositätsstandard 20,00 °C, 21,00 °C, 22,00 °C, 23,00 °C, 24,00 °C und 25,00 °C, VWR®, Viscometry Standards, 2162/10, Viskosität bei 25 °C: 498,1 mPa·s, Testmethode: ASTM D2162 / ASTM D352, Packung: Glasflasche
Artikel-Nr: 99407.260
VE: 1 * 500 mL
Lieferant: VWR Chemicals

Beschreibung: Kegel-Platte-Viskositätsstandard 20,00 °C, 21,00 °C, 22,00 °C, 23,00 °C, 24,00 °C und 25,00 °C, VWR®, Viscometry Standards, 2162/8, Viskosität bei 25 °C: 351,1 mPa·s, Testmethode: ASTM D2162 / ASTM D350, Packung: Glasflasche
Artikel-Nr: 99427.260
VE: 1 * 500 mL
Lieferant: VWR Chemicals

Beschreibung: Hochtemperatur-Viskositätsstandard, 20 °C bis 150 °C, VWR®, Viscometry Standards, S200S, Viskosität: (60 °C) 57,98 mPa s, Packung: Glasflasche
Artikel-Nr: 99495.260
VE: 1 * 500 mL
Lieferant: VWR Chemicals

Beschreibung: Hochtemperatur-Viskositätsstandard, 20 °C bis 150 °C, VWR®, Viscometry Standards, S8000S, Viskosität: (60 °C) 1533 mPa s, Packung: Glasflasche
Artikel-Nr: 99498.260
VE: 1 * 500 mL
Lieferant: VWR Chemicals

Beschreibung: Hochtemperatur-Viskositätsstandard, 20 °C bis 150 °C, VWR®, Viscometry Standards, S20S, Viskosität: (60 °C) 7,806 mPa s, Packung: Glasflasche
Artikel-Nr: 99492.260
VE: 1 * 500 mL
Lieferant: VWR Chemicals

Beschreibung: Kegel-Platte-Viskositätsstandard 20,00 °C, 21,00 °C, 22,00 °C, 23,00 °C, 24,00 °C und 25,00 °C, VWR®, Viscometry Standards, 2162/15, Viskosität bei 25 °C: 3993 mPa·s, Testmethode: ASTM D2162 / ASTM D358, Packung: Glasflasche
Artikel-Nr: 99412.260
VE: 1 * 500 mL
Lieferant: VWR Chemicals

Beschreibung: Hochtemperatur-Viskositätsstandard, 20 °C bis 150 °C, VWR®, Viscometry Standards, S60S, Viskosität: (60 °C) 20,05 mPa s, Packung: Glasflasche
Artikel-Nr: 99493.260
VE: 1 * 500 mL
Lieferant: VWR Chemicals

Beschreibung: Kegel-Platte-Viskositätsstandard 20,00 °C, 21,00 °C, 22,00 °C, 23,00 °C, 24,00 °C und 25,00 °C, VWR®, Viscometry Standards, 2162/20, Viskosität bei 25 °C: 20077 mPa·s, Testmethode: ASTM D2162 / ASTM D363, Packung: Glasflasche
Artikel-Nr: 99418.260
VE: 1 * 500 mL
Lieferant: VWR Chemicals

Beschreibung: Hochtemperatur-Viskositätsstandard, 100 °C, 110 °C, 120 °C, 130 °C, 140 °C und 150 °C, VWR®, Viscometry Standards, S600HT, Viskosität: (100 °C) 36,15 mPa s, Packung: Glasflasche
Artikel-Nr: 99504.260
VE: 1 * 500 mL
Lieferant: VWR Chemicals

Beschreibung: Kegel-Platte-Viskositätsstandard 20,00 °C, 21,00 °C, 22,00 °C, 23,00 °C, 24,00 °C und 25,00 °C, VWR®, Viscometry Standards, 2162/18, Viskosität bei 25 °C: 10030 mPa·s, Testmethode: ASTM D2162 / ASTM D361, Packung: Glasflasche
Artikel-Nr: 99415.260
VE: 1 * 500 mL
Lieferant: VWR Chemicals

Beschreibung: Hochtemperatur-Viskositätsstandard, 20 °C bis 150 °C, VWR®, Viscometry Standards, S30000S, Viskosität: (60 °C) 4897 mPa s, Packung: Glasflasche
Artikel-Nr: 99499.260
VE: 1 * 500 mL
Lieferant: VWR Chemicals

Beschreibung: Hochtemperatur-Viskositätsstandard, 25 °C, 60 °C und 135 °C, VWR®, Viscometry Standards, N600, Viskosität: (60 °C) 149,2 mPa s, Packung: Glasflasche
Artikel-Nr: 99500.260
VE: 1 * 500 mL
Lieferant: VWR Chemicals

Beschreibung: Viscosity standard, Nominally 50cSt at 40 and 7.3cSt at 100°, Specpure™, Viscometry Standards
Artikel-Nr: 47013.AP
VE: 1 * 500 mL
Lieferant: Thermo Fisher Scientific

Zertifikate


Beschreibung: Standard mit zertifizierten Werten bei 20 °C bis 100 °C, VWR®, Allgemeine Viskositätsstandards, N10, Viskosität bei 25 °C: 14,42 mPa·s, Testmethode: ASTM D2162, Packung: Glasflasche
Artikel-Nr: 99447.260
VE: 1 * 500 mL
Lieferant: VWR Chemicals

81 - 96 of 284