Sie suchten nach: Azadibenzocyclooctyne-NHS+ester,+with+4+carbon+linker


22 227  Ergebnisse wurden gefunden

SearchResultCount:"22227"

Sort Results

Listenansicht Hybridansicht

Bewerten Sie das Suchergebnis

Lieferant: Thermo Scientific
Beschreibung: Azadibenzocyclooctyne-NHS ester, with 4 carbon linker is used in various applications like protein-peptide conjugates, antibody-enzyme or antibody-drug conjugates, protein or peptide-oligonucleotide conjugates and surface modification.
Lieferant: Thermo Fisher Scientific
Beschreibung: Thermo Scientific Pierce DSS, also called disuccinimidyl suberate, is noncleavable and membrane permeable crosslinker that contains an amine-reactive N-hydroxysuccinimide (NHS) ester at each end of an 8-carbon spacer arm.
Artikel-Nr: (SIAL803642-50MG)
Lieferant: Merck
Beschreibung: The amine-reactive portion of SPDP reagents is the N-hydroxysuccinimide (NHS) ester. Reactions are most commonly performed in phosphate, carbonate/bicarbonate, or borate buffers at pH 7-8. Other buffers can be used provided they do not contain primary amines (or thiols or disulfide reducing reagents – see discussion of the sulfhydryl reactivity). The rate of reaction and degradation by hydrolysis increases with increasing pH; for example, the half-life of the NHS ester is several hours at pH 7 and less than 10 minutes at pH 9. NHS-ester reagents like SPDP and LC-SPDP have limited aqueous solubility and must be dissolved in organic solvent before adding them to a reaction mixture. Sulfo-NHS-ester reagents like Sulfo-LC-SPDP are water-soluble and can be added directly to aqueous reaction mixtures.
VE: 1 * 50 mg


Lieferant: Thermo Scientific
Beschreibung: Azadibenzocyclooctyne-PEG4-NHS ester (ADIBO-PEG4-NHS ester) is applied for protein-peptide conjugation, peptide-small molecule conjugation, 18F radiolabeling, protein-oligonucleotide conjugation and surface modification.
Artikel-Nr: (APOSBIB103-100MG)
Lieferant: Apollo Scientific
Beschreibung: Water soluble, used in sandwich ELISAs and in In Vivo tumor site localisationRef: Suter.M & Butler J.E (1986) Immunology letters 13, 313-316
VE: 1 * 100 mg


Artikel-Nr: (APOSOR322800-100MG)
Lieferant: Apollo Scientific
Beschreibung: SBAP (Succinimidyl 3-(bromoacetamido)propionate)
VE: 1 * 100 mg


Artikel-Nr: (BC97)
Lieferant: G-Biosciences
Beschreibung: Sulpho-NHS reacts primarily with primary amines to convert carboxyl groups to amine reactive sulfo-NHS esters. It is ideal for cross-linking, chemical labelling and solid support immobilisation. It is used to generate amine reactive esters from carboxylate groups and is primarily used to increase the efficiency of the carbodiimide EDC cross-linking. EDC reactions do not require Sulpho-NHS; however, its presence greatly enhances cross-linking efficiency and allows for a two-step process. EDC reacts with a carboxylate group to form an active ester, which is subject to rapid hydrolysis in aqueous buffers. The Sulfo-NHS increases the stability of the active intermediate and the resulting coupled product is identical to EDC reactions without sulpho-NHS.
VE: 1 * 500 mg


Artikel-Nr: (AATB7052)
Lieferant: AAT BIOQUEST INC
Beschreibung: ReadiCleave™ ROXtra succinimidyl ester contains a S-S linker that can be cleaved with TCEP or DTT to remove the ROXtra fluorophore from the target molecule.
VE: 1 * 1 mg

Neuer Artikel bei VWR!


Artikel-Nr: (AATB7002)
Lieferant: AAT BIOQUEST INC
Beschreibung: ReadiCleave™ AML ROXtra contains an azidomethyl linker that can be cleaved with TCEP to remove the ROXtra fluorophore from the target molecule.
VE: 1 * 1 mg

Neuer Artikel bei VWR!


Artikel-Nr: (AATB7008)
Lieferant: AAT BIOQUEST INC
Beschreibung: ReadiCleave™ AML XFD488 contains an azidomethyl linker that can be cleaved with TCEP to remove the Alexa Fluor® 488 fluorophore from the target molecule.
VE: 1 * 1 mg

Neuer Artikel bei VWR!


Artikel-Nr: (AATB7009)
Lieferant: AAT BIOQUEST INC
Beschreibung: ReadiCleave™ AML XFD546 contains an azidomethyl linker that can be cleaved with TCEP to remove the Alexa Fluor® 546 fluorophore from the target molecule.
VE: 1 * 1 mg

Neuer Artikel bei VWR!


Artikel-Nr: (AATB7053)
Lieferant: AAT BIOQUEST INC
Beschreibung: ReadiCleave™ iFluor® 700 succinimidyl ester contains a S-S linker that can be cleaved with TCEP or DTT to remove the iFluor® 700 fluorophore from the target molecule.
VE: 1 * 1 mg

Neuer Artikel bei VWR!


Artikel-Nr: (AATB7041)
Lieferant: AAT BIOQUEST INC
Beschreibung: ReadiCleave™ FAM SSL-NHS ester contains a S-S linker that can be cleaved with TCEP or DTT to remove the fluorescein (FITC) fluorophore from the target molecule.
VE: 1 * 1 mg

Neuer Artikel bei VWR!


Artikel-Nr: (AATB7050)
Lieferant: AAT BIOQUEST INC
Beschreibung: ReadiCleave™ Cy5-SSL-NHS ester contains a S-S linker that can be cleaved with TCEP or DTT to remove the Cy5 fluorophore from the target molecule.
VE: 1 * 1 mg

Neuer Artikel bei VWR!


Artikel-Nr: (AATB7012)
Lieferant: AAT BIOQUEST INC
Beschreibung: ReadiCleave™ AML XFD647 contains an azidomethyl linker that can be cleaved with TCEP to remove the Alexa Fluor® 647 fluorophore from the conjugated molecule.
VE: 1 * 1 mg

Neuer Artikel bei VWR!


Artikel-Nr: (AATB7003)
Lieferant: AAT BIOQUEST INC
Beschreibung: ReadiCleave™ AML iFluor® 700 contains an azidomethyl linker that can be cleaved with TCEP to remove the iFluor® 700 fluorophore from the target molecule.
VE: 1 * 1 mg

Neuer Artikel bei VWR!


Preis auf Anfrage
Lager für diesen Artikel ist begrenzt, kann aber in einem Lagerhaus in Ihrer Nähe zur Verfügung. Bitte stellen Sie sicher, dass Sie in sind angemeldet auf dieser Seite, so dass verfügbare Bestand angezeigt werden können. Wenn das call noch angezeigt wird und Sie Hilfe benötigen, rufen Sie uns an 1-800-932 - 5000.
Lager für diesen Artikel ist begrenzt, kann aber in einem Lagerhaus in Ihrer Nähe zur Verfügung. Bitte stellen Sie sicher, dass Sie in sind angemeldet auf dieser Seite, so dass verfügbare Bestand angezeigt werden können. Wenn das call noch angezeigt wird und Sie Hilfe benötigen, rufen Sie uns an 1-800-932 - 5000.
Dieses Produkt kann nur an eine Lieferadresse versandt werden die über die entsprechende Lizenzen verfügt. Für weitere Hilfe bitte kontaktieren Sie Ihr VWR Vertriebszentrum.
-Additional Documentation May be needed to purchase this item. A VWR representative will contact you if needed.
Dieses Produkt wurde von Ihrer Organisation gesperrt, lassen Sie sich gegebenenfalls ein Angebot zum Artikel erstellen.
Bitte kontaktieren Sie Ihren Einkauf für weitere Informationen.
Dieses Produkt ist Ersatz für den von Ihnen gewünschten Artikel.
Der mit diesem Symbol gekennzeichnete Artikel wird aus dem Programm genommen. Er ist nur noch bis zum Ende des Lagerbestands verfügbar. Sicher haben wir aber eine Alternative im Sortiment. Bei der Suche unterstützen wir Sie gerne! Wenden Sie sich dafür einfach an Ihre Ansprechpartner im Customer Service, Ihren Account Manager, Ihren Produktspezialisten oder unter 06151/39720 an unsere Zentrale in Darmstadt.
1 - 16 of 22 227
no targeter for Bottom